TABLE 5. Mean and standard deviation of percentage Ca2+ released from chick brain tissue slices. See Albert, E.N., Slaby, F., Roche, J. and Loftus, J.: Effect of amplitude-modulated 147 MHz radiofrequency radiation on calcium ion efflux from avian brain tissue, Radiat. Res. 109:19-27, 1987. The authors concluded that the EMF had no effect, but this was not true as assessed on the basis of the L test (L = 28.371, P < 0.0005). The overall effect was due almost equally to an effect of the EMF on variance (L = 14.314) and the mean (L = 14.057).

 

 Experiment Number

 Percentage Ca2+ Released From Tissue Slices In Test Chamber

 Percentage Ca2+ Released From Tissue Slices In Control Chamber

 1

 24.8 ± 3.1

23.0 ± 3.0 

 2

 15.4 ± 2.5

17.4 ± 4.7 

 3

 34.6 ± 2.1

32.2 ± 4.9 

 4

 45.6 ± 3.8

40.1 ± 0.7 

 5

 38.3 ± 5.2

40.7 ± 8.7 

 6

 26.4 ± 3.3

28.3 ± 4.8 

 7

 24.1 ± 2.9

 27.5 ± 2.1

 P < 0.0005, L test

 

Studies that reported a positive effect of EMFs on Ca++ include:

Bawin, S.M. and Adey, W.R.: Sensitivity of calcium binding in cerebral tissue to weak environmental electric fields oscillating at low frequency, Proc. Natl. Acad. Sci. USA 73:1999-2003, 1976;

Bawin, S.M., Adey, W.R. and Sabbot, I.M.: Ionic factors in release of 45Ca++ from chick cerebral tissue by electromagnetic fields, Proc. Natl Acad. Sci. USA 75:6314-6318, 1978;

Blackman, D.F., Elder, J.A., Weil, C.M., Benane, S.G., Eichinger, D.C. and House, D.E.: Induction of calcium ion efflux from brian tissue by radio-frequency radiation: Effects of modulation frequency and field strength, Radio Sci. 14(6S):93-98, 1979;

Adey, W.R.: Frequency and power windowing in tissue interactions with weak electromagnetic fields, Proc. IEEE 68:119-125, 1980;

Blackman, C.F., Benane, S.H., Elder, J.A., House, D.E., Lampe, J.A. and Faulk, J.M.: Induction of calcium ion efflux from brain tissue by radiofrequency radiation: Effect of sample number and modulation frequency on the power-density window, Bioelectromagnetics 1:35-43, 1980;

Blackman, C.F., Benane, S.G., Joines, W.T., Hollis, M.A. and House, D.E.: Calcium ion efflux from brain tissue: Power density versus internal field intensity dependencies at 50 MHz RF radiation, Bioelectromagnetics 1:277-283, 1980.


Back to Point 3


 Marino Home Page